Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSPECTION PENETRANT
Definition:
AN OIL OR ESTER BASE LIQUID USED WITH A DEVELOPER TO DETECT SURFACE FLAWS IN METALS, CERAMICS, GLASS, AND SOME PLASTICS. PENETRANTS WILL REVEAL ONLY DEFECTS WHICH ARE OPEN TO THE SURFACE AND WHICH ARE OF SUFFICIENT MAGNITUDE TO PERMIT ENTRANCE OF THE PENETRANT BY CAPILLARY ACTION. THE PENETRANT REMAINS IN THE OPENING UNTIL IT IS WITHDRAWN BY THE GREATER CAPILLARY ACTION OF THE DEVELOPER.
CAGE Information
Code | Company |
---|---|
37676 | ILLINOIS TOOL WORKS INC. DBA MAGNAFL |
Federal Supply Class
Title
MISCELLANEOUS CHEMICAL SPECIALTI
Inclusions:
INCLUDES ANTIFOGGING COMPOUNDS; WETTING AGENTS; ETCHING AND FOUNTAIN SOLUTIONS FOR LITHOGRAPHING; BLANKET REPAIR SOLUTIONS FOR LITHOGRAPHING; ANTIFREEZE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CNFQ | PENETRANT TYPE FOR WHICH DESIGNED | NONFLUORESCENT |
BLBZ | WATER SOLUBLE FEATURE | NOT PROVIDED |
FEAT | SPECIAL FEATURES | ENOT RECOMMENDED FOR PLASTIC MATERIAL. RED IN COLOR WITH BLAND, OILY ODOR. MINIMUM PENETRATION TIME IS 2 TO 5 MINUTES AND SHOULD BE USED BETWEEN 40'F AND 125'F. COVERS ABOUT 65 SQUARE FEET BY VOLUME |
ARAW | MINIMUM FLASH POINT | 93.0 DEG CELSIUS |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 2 TYPE AND C METHOD |
AKKF | QUANTITY WITHIN EACH UNIT PACKAGE | 16.0 OUNCES |